Go top
Paper information

Novel approaches to assess the mechanical reliability of toughened glass insulators used in transmission lines

H. Santos, M.A. Sanz-Bobi

IEEE Transactions on Power Delivery Vol. 37, nº. 3, pp. 2083 - 2089

Summary:

Toughened glass insulators installed in overhead lines play a key role in maintaining the reliability and safety of power systems. The singular properties of toughened glass make this material particularly suitable for this application on account of its excellent dielectric properties, high mechanical strength and easiness of inspection. If the glass was damaged, it would shatter completely leaving the remaining part of the insulator, called stub, still providing mechanical connection and being easily detectable from the ground by a visual inspection. In this paper, the mechanical reliability of toughened glass insulators is investigated through the analyses of experimental data obtained from laboratory tests. First, the mechanical strength of the toughened glass in insulators and the relationship between its failing load and the geometry of the insulator are investigated by means of a novel analytical approach. Afterwards, the risk of mechanical failure of glass insulators and stubs, with the shell broken off, is analysed. The results show the mechanical reliability of glass insulators for different string configurations and for large and complex systems deployed in 220 kV and 400 kV transmission lines. Finally, the effect of the shattering rate on the reliability is studied under the most adverse conditions.


Spanish layman's summary:

En este artículo se presenta una investigación sobre la confiabilidad mecánica de los aisladores eléctricos de vidrio templado a través del análisis de datos experimentales obtenidos de pruebas de laboratorio. Esta confiabilidad se estima para diferentes configuraciones de cadenas y sistemas complejos desplegados en líneas de transmisión de 220 kV y 400 kV en las condiciones más adversas.


English layman's summary:

This paper presents an investigation of the mechanical reliability of toughened glass insulators through the analyses of experimental data obtained from laboratory tests. This reliability is estimated for different string configurations and complex systems deployed in 220 kV and 400 kV transmission lines under the most adverse conditions.


Keywords: Insulators , mechanical reliability , shattering , toughened glass , transmission lines


JCR Impact Factor and WoS quartile: 4,400 - Q2 (2022)

DOI reference: DOI icon https://doi.org/10.1109/TPWRD.2021.3103894

Published on paper: June 2022.

Published on-line: August 2021.



Citation:
H. Santos, M.A. Sanz-Bobi Novel approaches to assess the mechanical reliability of toughened glass insulators used in transmission lines. IEEE Transactions on Power Delivery. Vol. 37, nº. 3, pp. 2083 - 2089, June 2022. [Online: August 2021]


    Research topics:
  • Smart industry: life cycle analysis and asset management
  • Smart industry: maintenance, reliability and diagnosis with self and deep learning techniques
  • Energy data analytics

pdf Preview