Go top
Conference paper information

Voltage saturation anti-windup for harmonic controllers in multiple reference frames

M. Ochoa, S. D'Arco, J.A. Suul

IEEE International Conference on Industrial Technology - ICIT 2015, Seville (Spain). 17-19 marzo 2015


Summary:

The output voltage references in grid connected Voltage Source Converters must be limited according to the available dc voltage to avoid over-modulation and windup of the current controllers. This may be especially critical for Active Power Filters (APFs), since uncontrolled over-modulation can cause unintended harmonics in the output voltage and interfere with the harmonic compensation. This paper presents an antiwindup mechanism for harmonic current controllers in Multiple Reference Frames (MFRs), which prevents controller windup. The proposed method extends the harmonic compensation capability by allowing operation of each harmonic controller into the non-linear modulation region. This is achieved by selective conditional integration of the errors in each reference frame. Simulation results are presented to demonstrate the effectiveness of the proposed anti-windup mechanism.


Keywords: Active Filtering, Anti-windup, Microgrids, Multiple-reference-frame Control, Voltage saturation


DOI: DOI icon 10.1109/ICIT.2015.7125412

Publication date: March 2015.



Citation:
Ochoa, M., D'Arco, S., Suul, J.A., Voltage saturation anti-windup for harmonic controllers in multiple reference frames, IEEE International Conference on Industrial Technology - ICIT 2015, Seville (Spain). 17-19 March 2015.

IIT-15-027A

Request Request the document to be emailed to you.