Ir arriba
Información del artículo en conferencia

Conducted and radiated interference measurements in the line-pantograph system

B. Tellini, M. Macucci, R. Giannetti, G. Antonacci

17th IEEE Instrumentation and Measurement Technology Conference - IMTC 2000, Baltimore (Estados Unidos de América). 01-04 mayo 2000


Resumen:
We present the results of a measurement campaign aimed at investigating electromagnetic interference phenomena in the interaction between overhead railway power supply lines and pantograph. In order to obtain such data, an experimental setup was assembled in a shielded room, consisting in a short section of overhead line and a full scale pantograph. One of the most interesting results consists in the observation of a very significant (both from the qualitative and the quantitative point of view) difference between the EMI behavior in the switch-on (pantograph going up) and switch-off (pantograph going down) transients.


DOI: DOI icon https://doi.org/10.1109/IMTC.2000.846905

Publicado en: , pp: 457-460

Fecha de publicación: 01-feb-2000


Cita:
B. Tellini, M. Macucci, R. Giannetti, G. Antonacci, "Conducted and radiated interference measurements in the line-pantograph system", presentado en 17th IEEE Instrumentation and Measurement Technology Conference - IMTC 2000, Baltimore, Estados Unidos de América, 01-04 mayo 2000, pp. 457-460, doi: 10.1109/IMTC.2000.846905

    Grupos de investigación:
  • Instituto de Investigación Tecnológica (IIT)

IIT-00-117A

pdf Solicitar el artículo completo a los autores