16th IFAC World Congress - IFAC, Praga (República Checa). 04-08 Julio 2005
Resumen:
This paper presents an algorithm based on a repetitive-control scheme to eliminate the low-frequency-harmonic contents of the output voltage in voltage- source inverters. The proposed controller can be used to minimise unexpected output-voltage harmonics due to practical implementation aspects of the pulse- width-modulation algorithm (switch dead time, for example). The controller can be implemented using the Park's transformation with a rotating reference frame for balanced three-phase voltage-source inverters. Simulation results are presented to illustrate the main contribution of this work
Palabras clave: Active Filters, Harmonic Control, Voltage Inverter Switches
Fecha de publicación: julio 2005.
Cita:
Roncero-Sánchez, P.L., Feliú, V., García-Cerrada, A., García-González, P., Repetitive-Control System for Harmonic Elimination in Three-Phase Voltage-Source Inverters, 16th IFAC World Congress - IFAC, Praga (República Checa). 04-08 Julio 2005.
IIT-05-005A