Improving AGC performance in power systems with regulation response accuracy margins using Battery Energy Storage System (BESS)

K. Doenges, I. Egido, L. Sigrist, E. Lobato, L. Rouco

IEEE Transactions on Power Systems Vol. 35, nº. 4, pp. 2816 - 2825

Resumen:
With the steady expansion of renewable energy sources (RES), the provision of ancillary services is becoming an increasingly challenging task within system operation. In order to add regulation capacity, battery energy storage systems (BESS) have been recognized as an efficient tool in recent literature. In this context, this paper proposes a novel BESS control strategy to improve dynamic performance of automatic generation control (AGC). Such control strategy is applicable to power systems which evaluate AGC performance utilizing regulation response accuracy margins, which typically define the slowest and fastest permitted power response to a regulation signal. The primary goal consists in enhancing the regulation service by minimizing the rate of non-compliance with respect to the corresponding dynamic performance criteria and its defined accuracy margins. Additionally a comprehensive State-of-Charge-control (SoC-control) is included in the strategy. By utilizing the BESS only during designated regulation assistance periods, preventing extreme levels of charge and furthermore identifying and avoiding futile regulation efforts, BESS degradation is kept to a minimum. To verify effectiveness a case study is conducted with 400 hours of real AGC operation of various BESS sizes. The obtained results show that a BESS is able to minimize the rate of non-compliance considerably, whilst preserving low BESS usage and degradation.


Palabras Clave: Secondary frequency regulation, Automatic Generation Control, Regulation performance, Battery Energy Storage System, State of Charge, Throughput.


Índice de impacto JCR y cuartil WoS: 6,663 - Q1 (2020); 6,600 - Q1 (2022)

Referencia DOI: DOI icon https://doi.org/10.1109/TPWRS.2019.2960450

Publicado en papel: Julio 2020.

Publicado on-line: Diciembre 2019.



Cita:
K. Doenges, I. Egido, L. Sigrist, E. Lobato, L. Rouco Improving AGC performance in power systems with regulation response accuracy margins using Battery Energy Storage System (BESS). IEEE Transactions on Power Systems. Vol. 35, nº. 4, pp. 2816 - 2825, Julio 2020. [Online: Diciembre 2019]


    Líneas de investigación:
  • Control automático de generación: diseño y ajuste de reguladores para el control automático de generación, identificación de modelos de unidades, servicios complementarios de regulación primaria y secundaria

pdf Previsualizar
pdf Solicitar el artículo completo a los autores